HANNA HI98192, portable WP EC / TDS / resistance / salt meter
Specifications HI98192 EC EC range: 0 to 400 mS / cm (displays values up to 1000 mS / cm actual conductivity) ** 0.001 to 9.999 μS / cm *, 10.00 to 99.99 μS / cm, 100.0 to 999, 9 μS / cm, 1,000 to 9,999 mS / cm, 10.00 to 99.99 mS / cm, 100.0 to 1000.0 mS
- Discreet verpakt!!
- Voor 14:00 besteld, dezelfde dag nog verstuurd!
- Gratis verzending vanaf €250,-
- More information? Contact us about this product
Specifications HI98192 EC
EC range: 0 to 400 mS / cm (displays values up to 1000 mS / cm actual conductivity) ** 0.001 to 9.999 μS / cm *,
10.00 to 99.99 μS / cm, 100.0 to 999.9 μS / cm, 1,000 to 9,999 mS / cm, 10.00 to 99.99 mS / cm, 100.0 to 1000.0 mS / cm (auto ranging)
Resolution: 0.001 μS / cm *, 0.01 μS / cm, 0.1 μS / cm, 0.001 mS / cm, 0.01 mS / cm, 0.1 mS / cm
Accuracy: ± 1% of reading (± 0.01 μS / cm or 1 digit, whichever is greater)
Calibration: Auto up to 5 points with 7 stored standards (0.00 μS / cm, 84.0 μS / cm, 1.413 mS / cm, 5.00 mS / cm, 12.88 mS / cm, 80.0 mS / cm , 111.8 mS / cm)
TDS Range: 0.00 to 99.99ppm, 100.0 to 999.9ppm, 1,000 to 9,999g / L, 10.00 to 99.99g / L, 100.0 to 400.0g / L (auto ranging)
Resolution: 0.01ppm, 0.1ppm, 0.001g / L, 0.01g / L, 0.1g / L
Accuracy: ± 1% of reading (± 0.05ppm or 1 digit, whichever is greater)
resistivity
Range: 1.0 to 99.9 Ω • cm, 100 to 999 Ω • cm, 1.00 to 9.99 KΩ • cm, 10.0 to 99.9 KΩ • cm, 100 to 999 KΩ • cm,
1.00 to 9.99 MΩ • cm, 10.0 to 100.0 MΩ • cm * (auto adjust)
Resolution: 0.1 Ω • cm, 1 Ω • cm, 0.01 KΩ • cm, 0.1 KΩ • cm, 1 KΩ • cm, 0.01 MΩ • cm, 0.1 MΩ • cm *
Accuracy: ± 1% of reading (± 10 Ω or 1 digit, whichever is greater)
Salinity
Range:% NaCl: 0.0 to 400.0%, Practical Salinity: 0.00 to 42.00 (PSU), Seawater Scale: 0.00 to 80.00 (ppt) / Resolution: 0.1%, 0.01
Accuracy: ± 1% of reading / Calibration: Max one point only in NaCl range with HI7037 standard, use conductivity
calibration for all other ranges
Temp Range: from -20.0 to 120.0 ° C / Resolution: 0.1 ° C / Accuracy: ± 0.2 ° C (excluding probe error) / Calibration: 1 or 2 points
Additional specifications
• EC Electrode for. HI-98192: HI-763133 platinum, four-ring conductivity / TDS probe with internal temperature sensor and 1m (3.3 ') cable (included)
• Cell constant setup: 0.010 to 10,000
• Temperature compensation: NoTC, linear (-20.0 to 120.0 ° C, non-linear (0 to 36 ° C) ISO / DIS 7888 std
• Reference temperature: 15 ° C, 20 ° C and 25 ° C
• Temperature coefficient: 0.00 to 10.00% / ° C
• TDS factor: 0.40 to 1.00
• DATA LOGGING: Log-on-demand: 400 samples, logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max. 1000 samples)
• Saved profiles up to 10
• Measurement modes: auto range, auto lock, lock and fixed range
• PC connectivity: opto-isolated sealed USB (with HI92000 software and micro USB cable)
• 4x 1.5V AA batteries / lifespan +/- 100 hours continuous without backlight (+/- 25 hours with backlight) cht 185x93x35,2mm / 400gram
Brand | Hanna |
Article code | EGS-0528 |
SKU | 528 |